Incorrect unit divisor in LM-SENSORS-MIB graph definitions

Description

The graph definitions for LM-SENSORS-MIB temperature and voltage sensors perform division by 1024 when the MIB specifies the units as mC and mV respectively. The error introduced is probably less than that introduced by most sensors, but it makes the definitions very confusing to read.

Acceptance / Success Criteria

None

Lucidchart Diagrams

Activity

Show:

Ronny Trommer April 1, 2016 at 8:22 PM

seems to be fixed, can we delete this branch? https://github.com/OpenNMS/opennms/tree/jira/NMS-7766

Seth Leger July 28, 2015 at 2:14 PM

This was already merged into foundation. Marking as fixed.

commit 21044e08a3b23f2f6f2d3269812f886b9f1a0e61

Seth Leger July 22, 2015 at 4:05 PM

Resurrected the Bamboo branch for this, I'll merge if it passes.

Jeff Gehlbach June 29, 2015 at 4:31 PM

Pushed in a branch, will merge once green.