Cannot process SNMPv3 Informs due to random Engine ID associated with users

Description

A customer has reported a problem on Trapd when receiving SNMPv3 Informs. Upon restarting OpenNMS, Trap stops processing Informs, and the following error appears on the log:

On the source code, a random Engine ID is associated with each USM User defined in trapd-configuration.xml, which is the behavior when an explicit ID is not passed when creating the UsmUser object, and I believe this is the source of the problem.

Acceptance / Success Criteria

None

Lucidchart Diagrams

Activity

Show:

Chandra Gorantla February 18, 2020 at 5:41 PM

Jeff Gehlbach February 4, 2020 at 8:52 PM

Poking at this in a Vagrant lab now.

Alejandro Galue January 13, 2020 at 7:57 PM

The problem could affect all Meridian versions as the UsmUser handling dates from 2011, but for now, I've added M2018 and M2019 to the list.