The default
opennms.properties
file fails to mention that the following properties should be set any time data collection and/or polling intervals are altered on a system persisting data to Newts:org.opennms.newts.query.minimum_step=30000 org.opennms.newts.query.heartbeat=45000
The values above are appropriate for a system collecting or polling any service every 30 seconds. The value of
heartbeat
should nominally be 1.5 times the value ofminimum_step
. The value ofminimum_step
should be set to the shortest collection interval configured for any collectable or pollable service on the system. These rules also apply for metrics collected via streaming telemetry.DOCUMENTATION (BR) 9/2/23
Add these two lines to the newts configuration topic (https://docs.opennms.com/horizon/31/deployment/time-series-storage/newts/newts.html ), number and list some of the additional information mentioned above as part of the numbered legend.